The Gas Analyzer 220 is your relia­ble part­ner for the pre­cise ana­ly­sis of up to six pro­cess gases in almost any indus­tri­al envi­ron­ment. This mul­ti-gas ana­ly­zer offers sta­te-of-the-art tech­no­lo­gy to meet the hig­hest stan­dards of accu­ra­cy, safe­ty and relia­bi­li­ty.

The Gas Analyzer 220 is a ver­sa­ti­le mul­ti-gas mea­su­ring device that has been spe­ci­al­ly deve­lo­ped for pre­cise online mea­su­re­ments of up to six pro­cess gases. Thanks to inte­gra­ted cross-sen­si­ti­vi­ty com­pen­sa­ti­on, unwan­ted inter­fe­rence is eli­mi­na­ted. With its design (19" rack) and the lar­ge num­ber of inter­faces, the device can be relia­bly inte­gra­ted into almost any plant pro­cess. The GA 220 ful­fills both legal and pro­cess-rele­vant requi­re­ments.

  • Many mea­sura­ble sub­s­tances:
    • Almost all IR-acti­ve sub­s­tances such as per­chlo­roe­the­ne, R11, R12, C-pen­ta­ne.
    • Oxygen (O₂), hydro­gen sul­phi­de (H₂S), hydro­gen (H₂).
  • Long-term sta­bi­li­ty: Long-life sen­sors gua­ran­tee high accu­ra­cy, mini­mal drift and redu­ced cali­bra­ti­on effort.
  • Ease of use: Intuitive 128 x 64 touch dis­play for clear mea­su­red values and simp­le menu navi­ga­ti­on in plain text.
  • Low main­ten­an­ce cos­ts: Robust design and relia­ble sen­sors redu­ce main­ten­an­ce and ope­ra­ting cos­ts.
  • Flexible inter­face opti­ons: RS232, Profibus DP, Ethernet IP, Modbus TCP, Profinet. Up to eight ana­log out­puts (4 - 20 mA) pos­si­ble.
  • Expandable inputs: Up to eight sam­ple gas inputs for ana­ly­zing mul­ti­ple sam­ple loca­ti­ons, even for sin­gle com­po­nent mea­su­re­ment.
  • Industrial design: Robust 19-inch housing (IP20) for indus­tri­al envi­ron­ments.
  • Optimized gas rou­ting: PTFE or stain­less steel gas rou­ting mini­mi­zes con­ta­mi­na­ti­on and ensu­res con­sis­tent mea­su­re­ment results.
  • Chemical indus­try: Monitoring of reac­tion pro­ces­ses.
  • Recycling: Analysis of sol­vents and ref­ri­ger­ants.
  • Pharmaceutical indus­try: qua­li­ty con­trol during pro­duc­tion.
  • Environmental tech­no­lo­gy: Measurement of emis­si­ons and con­trol of gas flows.
  • Monitoring: safe­ty checks and pro­cess con­trol in sen­si­ti­ve sys­tems.
  • Sample gas inputs: 1 (stan­dard), expan­da­ble up to 8
  • Measurement inter­val: 1 second (con­ti­nuous) or 20 seconds (qua­si-con­ti­nuous)
  • Measurement prin­ci­ple: NDIR sin­gle-beam method (cuvet­te hea­ted to 50 °C), elec­tro­che­mi­cal method (EC), zir­co­ni­um oxi­de ion con­duc­tor prin­ci­ple (ZrO₂)
  • Measurable gas com­pon­ents:
    • NDIR: per­chlo­roe­the­ne, R11, R12, C-pen­ta­ne and many other IR-acti­ve sub­s­tances
    • EC: inclu­ding oxy­gen (O₂), hydro­gen sul­phi­de (H₂S), hydro­gen (H₂)
    • ZrO₂: Oxygen (O₂)
  • Measuring ran­ge: 0 to 100 % by volu­me, depen­ding on sub­s­tance (we can also mea­su­re cer­tain sub­s­tances in the ppm ran­ge)
  • Measuring accu­ra­cy: Dependent on sub­s­tance
  • Gas flow rate: stan­dard 4 l/min, inter­nal gas rou­ting made of PTFE (optio­nal­ly stain­less steel)
  • Pressure tole­rance: 0.7 to 1.1 bar
  • Protection class: IP 20
  • Interfaces: RS232, Profibus DP, Ethernet Modbus TCP, Ethernet IP, Profinet, up to 8 ana­log out­puts (gal. Isolated) 4-20 mA, free­ly con­fi­gura­ble via dis­play menu
  • Operational rea­di­ness: Measurement rea­di­ness depen­dent on sub­s­tance, full spe­ci­fi­ca­ti­on achie­ved after 30 minu­tes
  • Operating vol­ta­ge: 230V AC / 50 Hz, 0.9 A / 207 VA
  • Dimensions: 19" rack, 400 mm depth
  • Weight: 13 kg

Interactive 360-degree view

Advantages

Maximum pre­cis­i­on in gas ana­ly­sis

Thanks to mea­su­re­ment tech­no­lo­gies such as NDIR, EC and ZrO₂, the Gas Analyzer 220 deli­vers high-pre­cis­i­on results even with com­plex gas mix­tures. The inte­gra­ted pres­su­re com­pen­sa­ti­on and the abili­ty to com­pen­sa­te for cross-sen­si­ti­vi­ties gua­ran­tee relia­ble mea­su­re­ments in every appli­ca­ti­on.

Flexibility for every pro­cess envi­ron­ment

With its adap­ta­ble design (eit­her desk­top housing or 19″ plug-in unit) and the opti­on of expan­ding to up to 8 sam­ple gas inputs, the GA 220 can be easi­ly inte­gra­ted into exis­ting sys­tems. This makes it per­fect for indus­tri­al appli­ca­ti­ons and a wide ran­ge of are­as.

High effi­ci­en­cy and low ope­ra­ting cos­ts

The GA 220 is cha­rac­te­ri­zed by its long-term sta­ble cali­bra­ti­on, which makes regu­lar reca­li­bra­ti­ons super­fluous. This mini­mi­zes main­ten­an­ce requi­re­ments and redu­ces ser­vice cos­ts – ide­al for eco­no­mic­al and trou­ble-free ope­ra­ti­on.

FAQ

What appli­ca­ti­ons is the Gas Analyzer 220 sui­ta­ble for?

The Gas Analyzer 220 was deve­lo­ped to ana­ly­ze pro­cess gases in a wide ran­ge of appli­ca­ti­ons. Whether in the che­mi­cal indus­try, phar­maceu­ti­cal indus­try, recy­cling sec­tor or envi­ron­men­tal tech­no­lo­gy - the GA 220 deli­vers pre­cise results and meets legal and safe­ty requi­re­ments. It is ide­al for pro­ces­ses whe­re seve­ral gases need to be mea­su­red simul­ta­neous­ly.

Which gases can be mea­su­red with the GA 220?

The GA 220 is capa­ble of ana­ly­zing up to 6 dif­fe­rent gases simul­ta­neous­ly:

  • NDIR (infrared): Perchloroethene, R11, R12, C-pen­ta­ne and many other IR-acti­ve sub­s­tances.
  • Electrochemical: inclu­ding oxy­gen (O₂), hydro­gen sul­phi­de (H₂S), hydro­gen (H₂).
  • ZrO₂ tech­no­lo­gy: oxy­gen (O₂).

Other gas com­pon­ents are available on request.

How is the Gas Analyzer 220 inte­gra­ted into exis­ting sys­tems?

The device offers maxi­mum fle­xi­bi­li­ty thanks to its modu­lar design:

  • Housing: Optionally as 19" rack-moun­ted or desk­top unit.
  • Connections: Standard RS232, optio­nal Ethernet IP, Modbus TCP, Profinet and ana­log out­puts (4-20 mA).
  • Sample gas inputs: 1 as stan­dard, expan­da­ble to up to 8.

These fea­tures allow easy inte­gra­ti­on into almost any indus­tri­al envi­ron­ment.

What advan­ta­ges does the GA 220 offer over com­pe­ting pro­ducts?

  • Long-term sta­bi­li­ty: Minimal cali­bra­ti­on requi­re­ments, saving time and cos­ts.
  • Robustness: Reliable ope­ra­ti­on in deman­ding con­di­ti­ons (tem­pe­ra­tures from 5° to 45°C, humi­di­ty up to 90 %).
  • Precision: Pressure com­pen­sa­ti­on and cross-sen­si­ti­vi­ty com­pen­sa­ti­on ensu­re exact mea­su­re­ments.

What ope­ra­ting cos­ts are asso­cia­ted with the GA 220?

The GA 220 was deve­lo­ped for eco­no­mic effi­ci­en­cy:

  • Low main­ten­an­ce: thanks to the sta­ble cali­bra­ti­on and robust com­pon­ents.
  • Low ener­gy cos­ts: Optimized inter­nal pumps and mea­su­re­ment tech­no­lo­gies.
  • Durability: High-qua­li­ty mate­ri­als and sophisti­ca­ted tech­no­lo­gy redu­ce repair requi­re­ments.

How quick­ly is the device rea­dy for use?

The Gas Analyzer 220 rea­ches its full spe­ci­fi­ca­ti­on in just 30 minu­tes after start-up. It is rea­dy for con­ti­nuous mea­su­re­ment rea­di­ness just five minu­tes after being swit­ched on.

What safe­ty func­tions does the GA 220 offer?

The GA 220 meets the hig­hest safe­ty stan­dards:

  • Pressure com­pen­sa­ti­on to pre­vent sys­tem fail­ures.
  • Optional: sam­ple gas fil­ters and pres­su­re regu­la­tors for inlet pres­su­res up to 100 bar.
  • Protected housing in accordance with pro­tec­tion class IP 20.

What ser­vice and sup­port opti­ons are available?

Fresenius Umwelttechnik offers a com­pre­hen­si­ve ran­ge of ser­vices:

  • On-site main­ten­an­ce and cali­bra­ti­ons.
  • Rental and repla­ce­ment equip­ment for short-term requi­re­ments.
  • Personal advice from experts for opti­mum inte­gra­ti­on into your pro­ces­ses.

How does the GA 220 help to com­ply with legal requi­re­ments?

The GA 220 enables pre­cise moni­to­ring of pro­cess gas com­pon­ents to ensu­re that your sys­tem com­pli­es with all rele­vant legal limits. This mini­mi­zes risks and increa­ses pro­cess safe­ty.

Can the Gas Analyzer 220 be adapt­ed to indi­vi­du­al requi­re­ments?

Yes, the device is high­ly con­fi­gura­ble:

  • Expandable sam­ple gas inputs.
  • Customizable data and com­mu­ni­ca­ti­on inter­faces.
  • Measuring ran­ges and com­pon­ents can be tail­o­red spe­ci­fi­cal­ly to your appli­ca­ti­ons.

Well? Interested?