Smart O2 Oxygen Analyzer | Precision & Efficiency by Environmental Technology

View with con­nec­tions

Smart O₂

The Smart O₂ offers relia­ble oxy­gen mea­su­re­ment with a zir­co­ni­um oxi­de sen­sor and Teflon gas rou­ting. It pro­vi­des pre­cise values with a mea­su­re­ment devia­ti­on of less than 0.5% per year, wit­hout the need for cali­bra­ti­on gases during ope­ra­ti­on.

The Smart O₂ is your first choice when it comes to pre­cise and relia­ble oxy­gen mea­su­re­ments in deman­ding indus­tri­al pro­ces­ses. Whether in the phar­maceu­ti­cal indus­try, che­mis­try, food pro­duc­tion, or air qua­li­ty moni­to­ring – this com­pact mea­su­ring device deli­vers accu­ra­te results and can be seam­less­ly inte­gra­ted into your exis­ting pro­ces­ses. Thanks to its robust design and long-term sta­ble mea­su­re­ment results, the Smart O₂ is ide­al for all appli­ca­ti­ons requi­ring con­ti­nuous oxy­gen moni­to­ring.

  • High-pre­cis­i­on zir­co­ni­um oxi­de sen­sor: Ensures con­stant and relia­ble mea­su­re­ments with a devia­ti­on of less than 0.5% per year.
  • Long-term sta­ble and low-main­ten­an­ce: Minimal cali­bra­ti­on requi­re­ments mean lower ope­ra­ting cos­ts and less down­ti­me.
  • Compact and robust design: With dimen­si­ons of W 310 mm x H 133 mm x D 221 mm, the Smart O₂ fits even in con­fi­ned sys­tems wit­hout com­pro­mi­sing per­for­mance.
  • Corrosion-resistant Teflon gas rou­ting: Durable and relia­ble, even with aggres­si­ve gases and harsh envi­ron­men­tal con­di­ti­ons.
  • Wear-free mea­su­re­ment tech­no­lo­gy: For pre­cise oxy­gen mea­su­re­ment wit­hout high fol­low-up cos­ts – no test gases requi­red during ope­ra­ti­on.

The SMART O₂ is indis­pensable in various indus­tries and appli­ca­ti­ons. Typical Areas include:

    • Pharmaceutical and Chemical Industry: Precise oxy­gen moni­to­ring in ste­ri­le and con­trol­led envi­ron­ments.
    • Food and Beverage Industry: Ensuring pro­duct qua­li­ty in pack­a­ging and bot­t­ling pro­ces­ses.
    • Environmental and Air Quality Monitoring: Precise mea­su­re­ments in indus­tri­al envi­ron­ments as well as indoors and in green­hou­ses.
    • Recycling and Waste Management: Monitoring of oxy­gen in recy­cling pro­ces­ses to pre­vent cor­ro­si­on and pro­cess dis­rup­ti­ons.
  • Sample gas inputs: Standard 1, expan­da­ble to up to 4 mea­su­ring points, to offer you maxi­mum fle­xi­bi­li­ty.
  • Measuring ran­ges: 0 – 5 vol. % / 0 – 50,000 ppm, 0 – 25 vol. % / 0 – 250,000 ppm, 5 – 95 vol. % / 50,000 – 950,000 ppm.
  • Measurement accu­ra­cy: ± 0.5% of the full sca­le value, for high­ly pre­cise and relia­ble results.
  • High-flow gas flow rate: 4.0 l/min, for a par­ti­cu­lar­ly fast respon­se time and to pre­vent delays in mea­su­re­ment results.
  • Pressure tole­rance: 0.7 to 1.1 bar.
  • Power sup­p­ly: 230 V / 50 Hz, sui­ta­ble for com­mon indus­tri­al requi­re­ments.
  • Housing dimen­si­ons: W 310 mm x H 133 mm x D 221 mm

Advantages

Cost effi­ci­en­cy through low-main­ten­an­ce ope­ra­ti­on

The Smart O₂ does not requi­re addi­tio­nal test gases during ope­ra­ti­on, which signi­fi­cant­ly redu­ces run­ning cos­ts. Thanks to its robust design and wear-free mea­su­re­ment tech­no­lo­gy, main­ten­an­ce remains mini­mal, which extends the ser­vice life of your sys­tem and pre­vents unplan­ned down­ti­mes.

Versatility for dif­fe­rent appli­ca­ti­ons

With the pre­cise zir­co­ni­um oxi­de sen­sor and fle­xi­ble con­fi­gu­ra­ti­on, the Smart O₂ offers a wide ran­ge of appli­ca­ti­on pos­si­bi­li­ties. The Smart O₂ adapts to your indi­vi­du­al requi­re­ments and ensu­res relia­ble mea­su­re­ment results in various envi­ron­ments.

Simple inte­gra­ti­on and ope­ra­ti­on

Thanks to the diver­se inter­faces such as ProfiBus, ProfiNet, and Ethernet IP, the Smart O₂ can be effort­less­ly inte­gra­ted into exis­ting sys­tems. The intui­ti­ve touch dis­play is easy to use and ensu­res relia­ble moni­to­ring of your pro­ces­ses at a glan­ce.

FAQ

Which appli­ca­ti­ons is the Smart O₂ sui­ta­ble for?

  • The Smart O₂ is desi­gned for a varie­ty of indus­tri­al appli­ca­ti­ons whe­re pre­cise and con­ti­nuous oxy­gen moni­to­ring is requi­red. Typical Areas are:

    • Pharmaceutical indus­try: Monitoring ste­ri­le envi­ron­ments and pro­ces­ses.
    • Food and Beverage Industry: Ensuring oxy­gen levels in pack­a­ging pro­ces­ses.
    • Chemical pro­ces­ses: Monitoring reac­tion con­di­ti­ons.
    • Air qua­li­ty moni­to­ring: Checking oxy­gen con­cen­tra­ti­ons in work envi­ron­ments and green­hou­ses.

    The Smart O₂ offers fle­xi­ble appli­ca­ti­on pos­si­bi­li­ties thanks to its exten­ded con­fi­gu­ra­ti­on opti­ons.

How accu­ra­te­ly does the Smart O₂ mea­su­re oxy­gen con­tent?

The Smart O₂ uses a zir­co­ni­um oxi­de sen­sor, known for its high accu­ra­cy. With a mea­su­re­ment accu­ra­cy of ± 0.5% of the full sca­le value, the device pro­vi­des relia­ble mea­su­re­ment results. It covers mea­su­ring ran­ges from 0 – 95 vol. % / up to 950,000 ppm.

Does the Smart O₂ requi­re regu­lar cali­bra­ti­ons?

The Smart O₂ is a low-main­ten­an­ce device that does not requi­re addi­tio­nal test gases during ope­ra­ti­on. Thanks to the long-term sta­ble sen­sors, mea­su­re­ment accu­ra­cy is main­tai­ned over a long peri­od, which mini­mi­zes main­ten­an­ce effort. However, occa­sio­nal checks may be advi­sa­ble depen­ding on the ope­ra­ting envi­ron­ment.

How many mea­su­ring points can the Smart O₂ moni­tor simul­ta­neous­ly?

The Smart O₂ comes stan­dard with one sam­ple gas input, but can be expan­ded to up to 4 mea­su­ring points. This allows you to simul­ta­neous­ly moni­tor mul­ti­ple pro­cess lines or mea­su­ring points wit­hout having to purcha­se addi­tio­nal devices.

Which gases can be mea­su­red with the Smart O₂?

The Smart O₂ is spe­ci­fi­cal­ly desi­gned for oxy­gen mea­su­re­ment (O₂). By using a zir­co­ni­um oxi­de sen­sor, the Smart O₂ can pre­cis­e­ly deter­mi­ne the oxy­gen con­tent in gas mix­tures. The mea­su­ring ran­ge extends from 0 – 5 vol. % / 0 – 50,000 ppm up to 95 vol. % / 950,000 ppm .

What are the ope­ra­ting cos­ts?

Since the Smart O₂ does not requi­re regu­lar con­sump­ti­on of test gases and the sen­sors are extre­me­ly dura­ble, the ope­ra­ting cos­ts remain low. The mini­mal­ly requi­red main­ten­an­ce also con­tri­bu­tes to redu­cing the total ope­ra­ting cos­ts. Overall, the Smart O₂ offers a very eco­no­mic­al solu­ti­on for oxy­gen mea­su­re­ments.

What is the gas flow rate?

The Smart O₂ ope­ra­tes with a gas flow rate of 4.0 l/min, which makes it par­ti­cu­lar­ly sui­ta­ble for appli­ca­ti­ons with high flow rate requi­re­ments. This high flow rate enables fast and accu­ra­te oxy­gen mea­su­re­ment, even in dyna­mic pro­ces­ses. It pre­vents delays in mea­su­re­ment results.

How robust is the Smart O₂ in chal­len­ging envi­ron­ments?

Thanks to the Teflon gas rou­ting and inter­nal fil­ters, the Smart O₂ is extre­me­ly robust and sui­ta­ble for use in cor­ro­si­ve envi­ron­ments or with aggres­si­ve gases. The pres­su­re tole­rance of 300 mbar to 1.5 bar also ensu­res sta­ble ope­ra­ti­on in a varie­ty of indus­tri­al appli­ca­ti­ons.

What inter­faces does the Smart O₂ offer for inte­gra­ti­on into my exis­ting sys­tem?

The Smart O₂ offers a wide sel­ec­tion of inter­faces for easy inte­gra­ti­on into your pro­ces­ses. These include ProfiBus, ProfiNet, Ethernet IP and ana­log out­puts such as 4 – 20 mA. These opti­ons ensu­re that the device can be inte­gra­ted into almost any exis­ting pro­cess con­trol sys­tem.

Can the Smart O₂ be ope­ra­ted in harsh envi­ron­ments?

Yes, the Smart O₂ is desi­gned for use in indus­tri­al envi­ron­ments. It can be used in an ope­ra­ting tem­pe­ra­tu­re ran­ge of -5 °C to +45 °C and is func­tion­al at a rela­ti­ve humi­di­ty of up to 90%. Its robust design makes it a relia­ble solu­ti­on even under dif­fi­cult con­di­ti­ons.

How lar­ge is the device and will it fit into my exis­ting sys­tem?

The Smart O₂ has a com­pact design with dimen­si­ons of W 310 mm x H 133 mm x D 221 mm and a weight of appro­xi­m­ate­ly 3.3 kg. This makes the device space-saving and allows for easy inte­gra­ti­on into various sys­tems and envi­ron­ments.

How easy is the Smart O₂ to ope­ra­te?

The Smart O₂ is equip­ped with a 128 x 64 touch dis­play, which enables intui­ti­ve ope­ra­ti­on. Thanks to the clear menu navi­ga­ti­on and the resis­ti­ve touch panel, mea­su­re­ments and con­fi­gu­ra­ti­ons can be made quick­ly and easi­ly.

What are the advan­ta­ges of the Smart O₂ com­pared to other oxy­gen ana­ly­zers?

The Smart O₂ offers high mea­su­re­ment accu­ra­cy, low ope­ra­ting cos­ts, and long-term sta­ble per­for­mance. With its robust design, fle­xi­bi­li­ty in the num­ber of mea­su­ring points, and ver­sa­ti­le inter­faces, it stands out from other devices. This com­bi­na­ti­on of relia­bi­li­ty, ver­sa­ti­li­ty, and ease of use makes it an ide­al choice for indus­tri­al appli­ca­ti­ons.

Well? Interested?