Stationary Analyzers
Stationary analyzers made by Fresenius Umwelttechnik are equipped with a built-in sample gas pump and a touch display. They are delivered pre-calibrated and incorporated into your process.
You can choose from all common data communication interfaces, optional measuring points, a comprehensive list of available substances and detectors, large measuring ranges and much more!
Advantages
- Direct display of measured values
- Long-term stability
- Low calibration effort
- Low service costs
- All common communication interfaces
- Easy operation via touch display
Gas Analyzer GA210
For stable and efficient online measurement in all kinds of processes
- Chemical industry
- Recycling
- Environment
- Monitoring
- Control
- Pharmaceuticals industry
- …and other fields
- Housing:
19 inch rack, 400 mm deep, IP 20 - Sample gas inlets:
1-inlet standard version, expandable to a max. of 8 inlets
Almost unlimited number of externally controllable sample gas inlets - Measuring ranges:
Depending on the gas - Number of gas components:
NDIR 1
EC 1 - Built-in sample gas pump
Optional data interfaces:
- Analogue, 4–20 mA
- Profibus
- Profinet
- Modbus TCP
- Ethernet IP
- NDIR
Single-beam principle, cuvette heated to 80 °C - EC
Electrochemical reaction procedure - Automatic zero adjustment
Paramagnetic Gas Analyzer GA210 O2
For measuring & monitoring the oxygen concentration in process gases
- Chemical industry
- Recycling
- Recycling of cooling appliances
- Environment
- Pharmaceuticals industry
- … and other fields
- Housing:
19 inch rack, 400 mm deep, IP 20 - Sample gas inlets:
1 + 2 calibration inlets (nitrogen, oxygen) - Measuring ranges:
0–25 Vol.-%
0–50 Vol.-%
0–100 Vol.-% - Paramagnetic measuring cell
- Built-in sample gas pump
Optional data interfaces:
- Analogue, 4–20 mA
- Profibus
- Profinet
- Modbus TCP
- Ethernet IP
- Paramagnetic measuring cell
Smart O2 Zirconium oxide
For precise and continuous oxygen measurement in industrial processes
- Pharmaceutical industry & laboratories (e. g. glove boxes)
- Breweries & beverage industry
- Packaging & vacuum systems
- Filling plants
- Combustion & heating boiler plants
- Greenhouses & biogas plants
- Gas generators
- Welding and soldering industry
- Microelectronics & semiconductor manufacturing
- Furnaces
- Air separation plants
- Gas mixing plants
- … and other fields
- Housing:
W 310 mm x H 133 mm x D 221 mm,
3 kg - Sample gas inlets:
1-inlet standard version, expandable to a max. of 4 inlets - Measuring ranges:
0–5 Vol.-%
0–25 Vol.-%
5–95 Vol.-% - Zirconium oxide sensor
- Built-in sample gas pump
- Zirconium oxide sensor
GA315 Hot Gas
Easy online measurement in e. g. combustion processes
- For measuring the exhaust gas of gas motors in biogas or landfill gas plants
- In gas flows with temperatures of up to 300 °C
- Industrial sector
- Waste disposal companies
- Energy production
- Monitoring
- Motor manufacturers
- … and other fields
- Housing:
19 inch rack, 400 mm deep - Sample gas inlets:
1 heated and controlled gas inlet at the front - No further sample gas processing required
- Built-in sample gas pump
Optional data interfaces:
- Analogue, 4–20 mA
- Profibus
- Profinet
- Modbus TCP
- Ethernet IP
- NDIR
Single-beam principle, cuvette heated to 85 °C - Automatic zero adjustment
- Cross-sensitivity compensation
Toxical Inline Analyzer
TINA
Quick and efficient threshold value monitoring of toxic and explosive gas mixtures
- LEL monitoring (Lower Explosion Level)
- Solvent monitoring
- Surface treatment
- Industrial applications
- … and other fields
- Housing:
Electronic housing, die-cast aluminium according to IP 67,
Weight: approx. 1.5 kg - Outputs:
1 x 4–20 mA analogue output - Number of gas components:
1 IR-active substanc - Measuring ranges:
On request
- Diffusion (required gas flow: 1 l/min)
- NDIR
- Automatic zero adjustment
Thermal conductivity detector
FTC300
Detector for measuring quantitative gas compositions
- H2 measurement in biogas as well as in furnaces of the metal industry / block-type thermal power stations / turbogenerators
- H2 or N2 measurement in elemental analysis
- Helium recovery monitoring
- Helium measurement with moisture compensation in airships
- Monitoring in air separation plants
- Control, monitoring and quality control of gas mixtures and pure gases
- … and other fields
- Wall-mounted housing:
W 145 x H 80 x D 85 mm - Interface: RS232
- Power supply: 18 V-36 V DC /700 mA
- Display: LCD display
- Operation via 3 buttons
- Linearity: < 1 % of the measuring range
- Warm-up time: approx. 20 minutes (for measurements in the smaller measuring range approx. 1 h)
- Flow rate: 10 l/h – 150 l/h
- T90 time: <1 sec at flow rates beyond 60 l/h and disabled electronic averaging
- Sample gas pressure: 200 hPa (0.2 bar) to 200 kPa (20 bar)
- Sample gas temperature: <60 °C
- Signal noise: <10 ppm H2 in N2
- Works according to the thermal conductivity principle
- Classic two-point calibration or simple one-point calibration
- Compensation of the cross-sensitivity and susceptibility to interference upon input of an external signal
- Multi gas mode for the sequential measurement of 16 binary gas mixtures
- Electrically isolated 0/4-20 mA output with free determination of the associated gas concentrations
- Precise linearization for binary gas mixtures H2, He, CO2, CH4 in N2 or Ar and N2 in Ar or Ar and N2 in Ar in a read-only memory
Smart Control 300
For monitoring the threshold value concentrations of gas mixtures containing solvents
- Solvent monitoring
- Surface treatment
- Industrial applications
- … and other fields
- Housing:
W 310 x H 133 x D 221 mm - Sample gas inlets:
1-inlet standard version, expandable to a max. of 2 inlets - Number of gas components:
- NDIR 1 (Perchlorethylene, trichloroethylene, dichloromethane or hydrocarbon solvent)
- Measuring ranges:
On request - Built-in sample gas pump
- NDIR
Single-beam principle, cuvette heated up to 80 °C - EC
Electrochemical reaction procedure - Automatic zero adjustment
Mercury Analyzer
Supersensitive mercury analyser for the continuous measurement of mercury in gas and water
Hg emission/immission monitoring, HG monitoring
- Water, water bodies and ground
- Natural gas
- Workplaces (MWC)
- Chemical separation procedures
- Physical adsorption procedures
- Recycling procedures
- Chemical electrolysis
- Medical / dental devices including gas bags
- … and other fields
- Housing:
19 inch rack, / 3 units, 450 mm deep - Sample gas inlets:
1-inlet standard version
Almost unlimited number of externally controllable sample gas inlets - Measuring ranges:
Selectable measuring ranges
Gas: 0–1/10/100/1000 µg/Nm3
Water: 0–10 µg Hg/l, 0–30 mg Hg/l - Sample connection: 1/4 inch-6/4 mm PFA hose
- Gas flow: 100–200 Nl/h
- Alarm signal: adjustable 4x potential-free changeover contact
- Single-beam photometer
- No adjustment required
- Highly Sensitive
- No calibration, no zero
- Fully digitally controlled
- interference filter
- Integrated flow meter with needle valve
Gas Analyzer for Formaldehyde in Ambient Air
Reliable formaldehyde measurement in the ppb range
- Electric fence monitoring
- Biogas plants
- Construction of new buildings
- Production of wooden products
- Traffic emissions
- Ambient air quality
- Occupational safety
- … and other fields
- Detection limit: < 1ppb
- Dimensions: W 484 x H 139 x D 440 mm
- Weight: 13 kg
- Response time: 10 sec – a few minutes
- Accuracy: beyond 5 %
- Temperature and pressure stability
- Interfaces: Ethernet, USB
- Combination of photoacoustic infrared spectroscopy and QC laser
Gas Analyzer GA220
Stable and efficient online measurement in all kinds of processes
- Chemical technology
- Recycling
- Environmental technology
- Monitoring
- Control
- Pharmaceuticals industry
- … and other fields
- Housing:
19 inch rack, 400 mm deep, IP 20 - Sample gas inlets:
1-inlet standard version, expandable to a max. of 8 inputs
Almost unlimited number of externally controllable sample gas inlets - Number of gas components:
IR 1-3
EC 1-3 - Built-in sample gas pump
Optional Data Interfaces:
- Analogue, 4–20 mA
- Profibus
- Profinet
- Modbus TCP
- Ethernet IP
- NDIR
Single-beam principle; cuvette heated up to 80 °C - EC
Electrochemical reaction procedur - Automatic zero correction
- Cross-sensitivity compensation
Gas Analyzer GA320
Precise and efficient online measurement in all kinds of processes
- Chemical technology
- Recycling
- Environmental technology
- Monitoring
- Control
- Pharmaceuticals industry
- … and other fields
- Housing:
19 inch rack, 400 mm deep - Sample gas inlets:
1-inlet standard version, expandable to a max. of 6 inputs
Almost unlimited number of externally controllable sample gas inlets - Number of gas components:
NDIR 1–6 - Built-in sample gas pump
- Built-in PC
- Low and high-precision detection limits
Optional Data Interfaces:
- Analogue, 4–20 mA
- Profibus
- Profinet
- Modbus TCP
- Ethernet IP
- NDIR
Single-beam principle, cuvette heated up to 85 °C - Automatic zero adjustment
- Cross-sensitivity compensation
BioBasic
Efficient online measurement of biogases
- Biogas plants
- Wastewater treatment plants
- Landfill plants
- … and other fields
- Wall-mounted housing:
IP 54, W 400 x H 400 x D 220 mm - Sample gas inlets:
1-inlet standard version, expandable to a max. of 5 inputs - Number of gas components:
CH4 and CO2 via NDIR
H2S, O2, H2 via EC - Measuring ranges:
CH4 = 0–100 Vol.-%
H2S = 0–2000 ppm
(optional) 0–10000 ppm
CO2 = 0–65/100 Vol.-%
O2 = 0–25 Vol.-%
H2 = 0–2000 ppm - Built-in sample gas pump
- Included accessories: flame arrestor (ATEX-certified), condensate separator incl. level monitoring and automatic shut-off, automatic condensate discharge with peristaltic pump
- NDIR
Single-beam principle, cuvette heated to 60 °C - EC
Electrochemical reaction procedure - Automatic zero adjustment
Smart BioBasic
Efficient online measurement of biogases
- Biogas plants
- Wastewater treatment plants
- Landfill plants
- … and other fields
- Wall-mounted housing:
IP 54, W 315 x H 300 x D 125 mm - Sample gas inlets:
1-inlet standard version, expandable to a max. of 2 inputs - Number of gas components:
CH4 and CO2 via NDIR
H2S and O2 via EC - Measuring ranges:
CH4 = 0–100 Vol.-%
CO2 = 0–65 Vol.-%
H2S = 0–2000 ppm
O2 = 0–25 Vol.-% - Built-in sample gas pump
- NDIR
Single-beam principle, cuvette heated to 60 °C - EC
Electrochemical reaction procedure - Automatic zero adjustment
- Cross-sensitivity compensation
Multi Gas Pump MGP 50
Efficient, reliable and mobile gas sampling system for field use
- Rehabilitation
- Investigation of contaminated sites
- Environmental analytics
- Laboratories
- … and other fields
- Portable system
Housing:
ABS plastic, W 660 x H 460 x D 200 mm,
14.6 kg - Gas sampling system
- Four-channel system with digital flow and volume control
- Flow control:
0.1 l/min–1.5 l/min
or 1 l/min–4 l/min - Volume control:
0.1 l–3000.0 l
- Micro-processor controlled flow and volume control
- Variably adjustable reference values plus pre-suction and sampling times