BioBasic Bionix Meeting the benchmark.

The benchmark: the process gas chromatograph

Online gas analyzer for biomethane. One reading every second for CH₄, CO₂, O₂ and H₂S, right at the grid injection point.

Scroll

BioBasic Bionix

Use the BioBasic Bionix to make sure your gas is on spec before grid injection.

Biomethane composition keeps changing, even after upgrading. Spot a change early and reliably, and you can correct it in time.

Use the BioBasic Bionix to make sure your gas is on spec before grid injection.

Proven in the field.

For six days the BioBasic Bionix ran at a biomethane grid injection plant right next to a process gas chromatograph, which sets the benchmark, and delivered highly accurate readings. On average, the two instruments were very close.

CH₄
< 0.3 vol.%
CO₂
≈ 0.1 vol.%
O₂
≈ 0.01 vol.%

Mean deviation from the process gas chromatograph across more than 500,000 one-second readings, drift close to zero.¹

Proven in the field.

One reading every second.

On speed, the BioBasic Bionix beats the benchmark. It measures continuously and shows every change as soon as the gas reaches the analyzer.

New reading

BioBasic Bionix
every second
Process GC
every few minutes
One reading every second.

You see changes before a gas chromatograph can report them.

In the field comparison the BioBasic Bionix readings were about 11 minutes ahead of the process gas chromatograph, so you can adjust the upgrading plant that much sooner.¹

Change visible

BioBasic Bionix
first
Process GC
about 11 min later
You see changes before a gas chromatograph can report them.

Considerably less expensive than a gas chromatograph.

The BioBasic Bionix costs considerably less than a process gas chromatograph, so one reading every second pays off even alongside the GC used for custody transfer.

Considerably less expensive than a gas chromatograph.

Measured against the benchmark.

Summarised from more than 500,000 one-second readings, these charts show how closely the BioBasic Bionix follows the process gas chromatograph and how much sooner it shows a change.

CH₄ over six days: both instruments show the same trendHourly means in vol.%, time-aligned
  • BioBasic Bionix
  • Process GC
Three hours in detail: the BioBasic Bionix sees the peak firstOne-minute values CH₄ in vol.%. At this peak 9 minutes, about 11 on average over the whole measurement.
  • BioBasic Bionix
  • Process GC
Mean deviation from the process GCDot: mean, line: spread, in vol.%
Values as a table
Daily means CH₄ in vol.%
BioBasic BionixProcess GC
Day 196.2996.55
Day 296.1496.37
Day 395.9496.29
Day 496.1196.36
Day 596.2396.44
Day 696.0196.30

¹ Field comparison at a biomethane grid injection plant in Germany, July 2026, after adjusting the calibration parameters. The test gas itself has an uncertainty of ±0.2 vol.% for CH₄. H₂S was not part of the comparison. The time lead depends on the GC cycle and the sample line. The BioBasic Bionix complements the process gas chromatograph used for custody transfer.

The four gases the BioBasic Bionix measures.

  • CH₄90–100 vol.%NDIR
  • CO₂0–10 vol.%NDIR
  • O₂0–30 vol.%electrochemical
  • H₂S0–100 ppmNDUV
The four gases the BioBasic Bionix measures.

A simple touch display with a modern Material Design interface.

Read the current value for each substance on its own tile and analyze the trends right on the display. Write the measurement data to a USB stick or evaluate it with the GasAnalyzer Connect app.

  1. Measuring displayFour gases with trend arrow and history.
  2. MenuAll functions in plain text.
  3. DisplayLight or dark, chart lines per reading.
  4. LanguageSeven languages, right on the device.

Example values

GasAnalyzer Connect app

  • Coming soon on Google Play
  • Coming soon on the App Store
A simple touch display with a modern Material Design interface.

See what your product gas is doing right now.

One reading every second. You will find all data, views and options of the BioBasic Bionix on the product page.

See what your product gas is doing right now.

Technical data (extract)

The BioBasic Bionix in figures

Technical data BioBasic Bionix, extract
Measuring intervalOne reading every second, continuous
Gas componentsCH₄, CO₂, O₂, H₂S
Measuring rangesCH₄ 90–100 vol.%, CO₂ 0–10 vol.%, O₂ 0–30 vol.%, H₂S 0–100 ppm
Measuring principleCH₄/CO₂: NDIR, O₂: electrochemical, H₂S: NDUV
Expanded uncertaintyCH₄ 0.2 %, CO₂ 0.5 %, O₂ 0.3 %, H₂S 0.5 % of full scale
Calibrationautomatic with span and zero gas, error-monitored, approx. 4 min per cycle
Sample transportinternal pump 4 l/min, optional pumpless from 60 mbar inlet pressure
Ambient conditions20–30 °C, air-conditioned indoor installation only
HousingWall-mounted housing 400 × 600 × 200 mm, IP 54, 18 kg
Interfaces4–20 mA and RS232, optional Profibus DP, Profinet, Ethernet IP, Modbus TCP
SafetyATEX-certified flame arrester at the sample inlet, speed-monitored fan

Extract, as of . The datasheet is always binding. Request datasheet

Frequently asked

Measuring biomethane: questions from practice

01How accurate is the BioBasic Bionix compared with a gas chromatograph?

In a field comparison at a biomethane grid injection plant, the mean deviation from the process gas chromatograph was below 0.3 vol.% for CH₄, around 0.1 vol.% for CO₂ and around 0.01 vol.% for O₂. The test gas itself has an uncertainty of ±0.2 vol.% for CH₄. H₂S was not part of the comparison.

02Does the BioBasic Bionix replace the process gas chromatograph?

No. The process gas chromatograph remains the instrument for custody transfer. The BioBasic Bionix complements it by measuring every second and showing swings that fall between two GC values.

03Which gases does the BioBasic Bionix measure?

CH₄ from 90 to 100 vol.% and CO₂ from 0 to 10 vol.% by NDIR, O₂ from 0 to 30 vol.% electrochemically and H₂S from 0 to 100 ppm by NDUV.

04How often does the analyzer deliver a reading?

Every second, continuously. Only during automatic calibration are no readings available, for about four minutes per cycle.

05How is the BioBasic Bionix calibrated?

Automatically with span and zero gas at an adjustable interval. Calibration is error-monitored, including limits for the calibration factor and offset.

06Where can the analyzer be installed?

In air-conditioned indoor rooms at 20 to 30 °C. The wall-mounted housing has protection class IP 54. The flame arrester at the sample inlet is ATEX-certified; the analyzer itself is not approved for hazardous areas.

Advice

Tory – your BioBasic Bionix advisor

Tell Tory where you want to measure your biomethane and which values you need. Tory clarifies the key points and puts you straight in touch with our team.

  • Measuring point and gas composition
  • Installation and interfaces
  • Direct path to a quote request

Let's talk about your grid injection.

Tell us your measuring point, gas composition and installation site. You get a concrete proposal. Faster: ask Tory in the chat at the bottom right.