6 min read 1,040 words
Your process gas chromatograph reports: everything within specification. A few minutes later, the same again. But what happened in between? That is exactly the gap the new BioBasic Bionix closes. The biomethane analyzer from Fresenius Umwelttechnik delivers a measured value every second for CH₄, CO₂, O₂, and H₂S – directly at the point of transfer to the gas grid.In this article, you’ll learn why continuous measurement makes biomethane quality safer, what the field comparison with a gas chromatograph revealed, and for which plants the device is worthwhile.Why biomethane quality needs more than just a GC Biomethane is upgraded biogas that may be fed into the natural gas grid once it meets grid specifications. Even after biogas upgrading, its composition still fluctuates. Anyone feeding it into the grid must detect these fluctuations early.The gas chromatograph remains the referenceThe process gas chromatograph provides the calibration-relevant values for billing. That doesn’t change. However, it operates in cycles of several minutes. What happens between two analyses remains invisible to it.The BioBasic Bionix complements it every secondThe BioBasic Bionix measures continuously, every second. The roles are clearly divided:GC: calibration-relevant reference for billingBioBasic Bionix: fast, process-near measurement for process controlThis allows you to adjust the upgrading process in time and keep biomethane injection within grid specifications.You can read about the requirements for grid injection in our article Biomethane Injection into the Natural Gas Grid. There, we explain in detail why the concept of continuous biomethane monitoring is gaining ground.What the BioBasic Bionix measures – and howThe BioBasic Bionix detects four substances in a single device. It uses a suitable measurement principle for each:SubstanceMeasuring rangeMeasurement principleMethane (CH₄)90–100 vol.%NDIRCarbon dioxide (CO₂)0–10 vol.%NDIROxygen (O₂)0–30 vol.%electrochemicalHydrogen sulfide (H₂S)0–100 ppmNDUV with reference detectorTechnical data (excerpt), as of datasheet version 10/20/2026. The datasheet is binding. NDIR stands for non-dispersive infrared measurement: the gas absorbs infrared light, and the concentration is derived from this absorption. NDUV works on the same principle in the ultraviolet range. The reference detector compensates for fluctuations in the light source.No sample gas conditioning needed for dry biomethaneDry biomethane requires no sample gas conditioning. An internal pump delivers 4 l/min. Optionally, the device operates pump-free from 60 mbar of inherent pressure.The field test: BioBasic Bionix versus gas chromatographIn the field comparison, the methane value deviated from the process gas chromatograph by less than 0.3 vol.% on average. For this test, we installed the BioBasic Bionix directly next to a GC at a biomethane injection plant in Germany. Both devices ran in parallel for six days in July 2026.GasAverage deviation from the process GCCH₄under 0.3 vol.%CO₂around 0.1 vol.%O₂around 0.01 vol.%These results are based on over 500,000 second-by-second values, measured after adjusting the calibration parameters. For reference: the test gas itself has an uncertainty of ±0.2 vol.% for CH₄. H₂S was not part of the comparison.Around eleven minutes aheadThe real advantage shows up in time: the BioBasic Bionix detected changes on average around eleven minutes earlier than the GC. How big the lead is in your case depends on the GC cycle and the sample line.You can find the diagrams for the field comparison on the BioBasic Bionix campaign page.In daily operation: easy to read, automatically calibratedA good measuring instrument barely draws attention during operation. The BioBasic Bionix is designed with this in mind.Operation via touchscreenOn the color touchscreen, you see a separate tile for each gas, showing the current value and trend. Measurement data can be saved to a USB stick. The GasAnalyzer Connect app is coming soon for Android and iOS. The device reports faults in plain language – plug & play instead of searching for error codes.Automatic, error-monitored calibration Calibration runs automatically with test and zero gas at an adjustable interval. Limit values are set for the calibration factor, standard deviation at the zero point, and offset. One cycle takes about four minutes; during this time, the device does not provide measured values.Interfaces for your process control systemsStandard interfaces are 4–20 mA (galvanically isolated) and RS232. Optionally available: Profibus DP, Profinet, EtherNet/IP, and Modbus TCP. This allows you to integrate the measured values directly into your control system.Installation and setupWall-mounted housing 400 × 600 × 200 mm, protection class IP 54, 18 kgInstallation in climate-controlled indoor spaces at 20–30 °CATEX-certified flame arrestor at the sample gas inlet, speed-monitored housing fan230 V AC / 50 Hz, alternatively 115 V AC / 60 Hz or 230 V / 60 HzThe device itself is designed for safe areas. If you need a solution for potentially explosive atmospheres, we’re happy to review this through our external partner network.Who benefits from the BioBasic Bionix?The BioBasic Bionix is built for anyone who produces, upgrades, or receives biomethane:Biomethane injection plants and operators of a biomethane plant Gas grid transfer stations Biogas upgrading Power-to-gas and SNG plantsAnother argument is the price: the BioBasic Bionix costs significantly less than a process gas chromatograph. A measured value every second pays off even alongside an existing GC.Frequently asked questions Does the BioBasic Bionix replace the gas chromatograph? No. The process gas chromatograph remains the calibration-relevant measuring instrument. The BioBasic Bionix complements it by making visible the fluctuations that occur between two GC readings.How often does the device provide a measured value? Every second, continuously. Measured values are only unavailable for about four minutes per cycle during automatic calibration.How does it differ from the BioBasic? The BioBasic is designed for biogas with multiple measuring points. The BioBasic Bionix specializes in biomethane after upgrading and measures continuously at a single point.Closing gaps, acting soonerThe BioBasic Bionix reveals what happens between two GC analyses. It measures CH₄, CO₂, O₂, and H₂S every second, has proven itself in field comparison, and costs significantly less than a gas chromatograph. For your biomethane injection, this means more safety and more time to react.Curious to learn more? In the BioBasic Bionix video, you can see the device in just two minutes. Technical data and a 3D view are available on the BioBasic Bionix product page.Planning a new measuring point? Request your quote now – we’re happy to advise you on your measurement task.